Northern Ireland Water
Project name |
Location |
Country |
Market area |
|
Northern Ireland Water |
Belfast |
UK |
In Situ Pipe Repair |
Requirement
Rising sewer main with zero life, running under a rail crossing and a busy dual-carriageway. Also situated very close to a high pressure gas main.
Preparation
Pipe interior was cleaned using low pressure water jetting, then dried using foam pigs.
Coatings
Corroless™ ACO Wasteseal at 6 mm
Product (per coat) |
DFT (per coat) |
Colour |
---|---|---|
Corroless™ ACO Wasteseal |
- |
- |
Comments:
- 14" (350mm) internal diameter steel rising main
- Up to 10 bar operating pressure
- Length - 3 sections totalling 100m
- No traffic or rail disturbance
- No ground disturbance